| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F11 | Drain fault | Clear filter/hoses; test drain pump. |
| F12/F13 | Inlet fault / water intake | Open supply; clean screens; test inlet valve/flow meter/WSH. |
| F14 | Wash pump/circulation fault | Test BLDC pump; replace pump module. |
| F24 | Heater relay/temperature rise | Test heater/NTC; replace relay/board. |
| F32 | Door lock fault | Replace lock/actuator; check alignment. |
| F70 | Leak detected (float switch) | Dry base; fix leak; reset float. |
| F78 | Circulation pump fault | Replace pump; check cabling. |
| F79 | Communication error | Inspect CAN harness; replace module. |
| F84 | AutoDos/Dispenser | Service cartridge motor; replace if jammed. |
| F01 | Electronics fault | Power reset; replace board if persistent. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F220/F221 | Temp sensor open/short | Ohm RTD; replace sensor/harness. |
| F460 | Cooling fan fault | Replace fan; verify airflow. |
| F447 | Door lock error | Service lock motor & microswitches. |
| F255 | Overheat/runaway | Check relays; replace power module. |
| F100 | Electronics fault | Power reset; replace board. |
| F111 | Ignition failure (gas) | Check igniters/valves/pressure. |
| F143 | Touch/UI error | Replace touch module; reseat ribbon. |
| F170 | Comms error | Inspect bus harness; replace module. |
| LOC | System lock active | Unlock via UI; confirm. |
| PF | Power fail | Clear; verify supply. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F1x | Sensor/NTC fault | Ohm sensors; replace NTC/board. |
| ALARM HI | High temp | Clean condenser; verify fans/compressor. |
| DOOR | Door open/switch | Adjust hinges; replace switch/gasket. |
| DF | Defrost error | Test heater/bi-metal/board output. |
| FAN | Evap/cond fan | Replace motor; check tacho/ice. |
| INV | Inverter fault | Measure DC bus; replace inverter/compressor. |
| ICE | Icemaker fault | Run test; replace module/valve. |
| UI | Comms/UI fault | Reseat connectors; replace UI/board. |
| Filter | Water filter reminder | Replace filter; reset. |
| PF | Power fail | Clear alarm. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F20 | Inlet fault | Open valves; clean screens; test inlet valve. |
| F21 | Drain fault | Clear pump/coin trap/hoses; replace pump. |
| F34 | Door lock fault | Replace lock/strike; check harness. |
| F53 | Motor fault | Test tach/speed control; replace drive. |
| F51 | Unbalance/tacho | Level; inspect shocks; check sensor. |
| F10 | Water level sensor | Check pressure hose; replace sensor. |
| F63 | Heater relay | Replace relay/power module; test element. |
| F138 | Leak detected | Inspect hoses/boot; reset float. |
| F92 | Communication fault | Inspect bus; replace module. |
| PF | Power fail | Clear; verify supply. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F55 | Airflow restriction | Clean filters/condensers/ducts; check blower. |
| F66 | NTC sensor fault | Replace thermistor/board channel. |
| F50 | Heater fault | Test heater/relay; replace power module. |
| F92 | Communication fault | Inspect harness; replace PCB. |
| F148 | Overheat protection | Check airflow; reset hi-limit. |
| F30 | Door switch/lock | Replace switch/lock; adjust strike. |
| F28 | Moisture sensor fault | Clean strips; replace sensor. |
| F20 | Inlet water fault (steam) | Open supply; test valve. |
| PF | Power failure | Clear; verify supply. |
| LOC | System lock active | Unlock via UI. |