We service Crosley kitchen and laundry products across Montreal. Many models share platforms with major OEMs, which helps with parts availability and fast repairs. One-year parts & labour warranty on our work.
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F1/F1-E0 | Main control fault | Reset; inspect harness; replace EOC if code returns. |
| F2 | Runaway temperature | Test RTD sensor & relays; replace failed part. |
| F3/F4 | Sensor open/short | Ohm RTD ~1080Ω @ 70°F; replace if out of spec. |
| F9 | Door lock fault (self-clean) | Test latch motor/switch; repair or replace assembly. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F9-E1 | Drain problem | Clear knockout/high loop/hoses; test drain pump. |
| F8-E1 | Fill fault | Clean inlet screen; test valve & pressure. |
| F7-E1 | Heater not heating | Test element/NTC; inspect control relay. |
| F4-E3 | Wash motor not running | Check harness; replace circulation motor as needed. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| PO | Power outage logged | Acknowledge; verify temps; monitor. |
| d | Door open | Adjust hinges; test switch/gasket. |
| E-sensor | Temp sensor out of range | Ohm sensors; replace NTC/control as needed. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F9-E1 | Long drain | Clear pump/hoses; replace drain pump if weak. |
| F8-E1 | Low/No fill | Open valves; clean screens; test inlet valve. |
| F5-E2 | Lid lock fault | Adjust strike; replace lock assembly. |
| F7-E1 | Shifter/speed sensor fault | Test actuator & wiring; replace actuator. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| AF / F4-E3 | Restricted airflow | Clean vent/duct; check blower & exhaust thermistor. |
| L2 | Low line voltage (electric) | Check breaker/receptacle/terminal block. |
| F01 | Main control failure | Inspect for thermal events; replace control if confirmed. |