| Fault/Code | Condition/Description | Solution |
|---|---|---|
| H | High temperature alarm | Clean condenser; verify fans; test sealed system. |
| d | Door open | Adjust hinges; replace switch/gasket if needed. |
| E1/E2 | Cabinet/evap sensor faults | Ohm NTCs; repair harness; replace sensor/control. |
| DF | Defrost error | Test heater/defrost sensor; replace failed part. |
| FAN | Evap/condenser fan fault | Test voltage & feedback; replace motor. |
| INV | Inverter/compressor comms | Test inverter DC & signals; replace inverter/compressor. |
| ICE | Icemaker error | Run harvest/fill tests; replace module/valve/tube heater. |
| FIL | Filter reminder | Replace filter; reset indicator. |
| CF | Control fault | Power reset; replace board if persistent. |
| PF | Power failure | Clear alarm; confirm dedicated circuit. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| H | Temp too high | Check door seal; test fans/compressor; defrost as needed. |
| d | Door ajar | Level cabinet; adjust door; replace switch. |
| E3/E4 | Evap sensor/defrost sensor | Ohm sensors; replace defective component. |
| DF | Defrost failure | Test heater/fuse; replace control if no drive. |
| FAN | Fan stall/no feedback | Replace fan motor; clear ice. |
| INV | Inverter/compressor error | Diagnose inverter/comp; replace as needed. |
| ICE | Ice maker fault (if equipped) | Test harvest/fill; replace IM/valve. |
| CF | Control PCB error | Replace board if persistent. |
| FIL | Filter reminder | Replace filter; reset. |
| PF | Power failure | Clear and retest. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| H/L | Temp high/low alarm | Verify setpoints; test sensors/fans. |
| E1/E2 | Cabinet/evap sensor fault | Ohm NTCs; replace if out of spec. |
| d | Door open | Adjust hinges/strike; replace switch/gasket. |
| FAN | Fan failure | Replace fan motor; clear ice/dust. |
| DF | Defrost error (dual-evap) | Test heater/defrost sensor; replace control if no drive. |
| LED | Lighting driver fault | Replace LED driver/module. |
| VIB | Excess vibration | Level unit; check feet; isolate compressor. |
| HUM | Humidity out of range | Service humidifier; replace sensor. |
| PF | Power failure | Clear alarm; verify circuit. |
| CF | Control fault | Replace control board. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| H | High temp alarm | Clean condenser; test fan; check gasket. |
| d | Door open | Adjust door; replace switch/gasket. |
| E1/E2 | Sensor fault | Ohm NTC; replace sensor/control. |
| DF | Defrost error | Test heater/fuse; replace control. |
| FAN | Fan stall | Replace motor; clear obstruction. |
| LED | Lighting/driver fault | Replace driver/module. |
| PF | Power failure | Clear alarm; verify supply. |
| CF | Control error | Replace control board. |
| HUM | Humidity out of range | Check gaskets/air leaks. |
| VIB | Vibration/noise | Level unit; isolate compressor. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| H2O | No water / low flow | Open valve; flush line; replace inlet valve. |
| ICE | No harvest | Test harvest motor/thermostat; replace module. |
| FIL | Filter reminder | Replace filter; reset. |
| d | Door switch open | Replace door switch. |
| FAN | Condenser fan fault | Replace fan motor. |
| CF | Control error | Replace control board. |
| PF | Power failure | Clear; verify supply. |
| HOT | High temp bin | Clean condenser; check airflow. |
| LOW | Low ice production | Check ambient/temp; sealed-system test. |
| LEAK | Internal leak | Inspect tubing/fittings; repair & test. |