We repair Liebherr built-in & freestanding refrigeration, columns, undercounter units and multi-zone wine cellars. OEM parts, meticulous diagnostics, and a one-year parts & labour warranty.
Our technicians are trained to focus on certain brands to improve efficiency
Give us a call, we will send a professional repairman to your home that specializes on your brand.
Liebherr Residential or Commercial appliances.
Flash Repair
BioFresh drawers, DuoCooling, precision NTC sensors and inverter systems are common on Liebherr. We stock fans, sensors, boards, inverters, dampers, valves, and door hardware for fast turnaround.
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| ALARM / HI TEMP | Compartment above setpoint | Clean condenser; verify fans; test sensors & compressor/inverter. |
| DOOR / dO | Door open timeout / switch | Adjust hinges; replace switch; inspect gasket. |
| SENSOR RF/FF/FZ | NTC out of range | Ohm & replace sensor; check harness/board. |
| FAN EVAP/COND | Fan speed/feedback error | Replace fan; clear debris; check tacho. |
| DEF / dF | Defrost failure | Test heater, thermal fuse/bi-metal; control output. |
| ICE / IM | Icemaker fault | Run service test; replace module/valve. |
| INV / COMP | Inverter/compressor start/comm error | Measure DC bus & windings; replace inverter/compressor. |
| UI / CF | UI ⇄ control comm fault | Reseat connectors; replace UI/control. |
| WTR / H2O | Water/Filter alert | Replace filter; purge air; check pressure. |
| PF | Power failure | Clear alarm; verify supply. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| HI TEMP / ALARM | Cellar warming | Check condenser, fans, seals; test sensors & drive. |
| SENSOR Z1/Z2 | Zone sensor out of range | Replace NTC; verify harness/board. |
| FAN Z1/Z2 | Evaporator fan error | Replace fan; clear obstruction; confirm tacho. |
| LIGHT | Lighting failure | Replace LED/driver; door switch. |
| HUM | Humidity module fault | Replace module; verify drain. |
| DEW | Condensation on glass | Verify gasket/ambient; heater operation (if equipped). |
| UI | Touch/UI unresponsive | Power reset; replace UI board. |
| PF | Power fail | Clear; verify supply. |
| LOCK | Control lock engaged | Disable via panel. |
| BUZ | Alarm beeper active | Resolve root fault; reset alarm. |
Monday to Friday
7:00am - 9:00pm
Saturday
10:00am - 5:00pm
Sunday
12:00am - 5:00pm