Danby Appliance Repair Montreal

Danby Appliance Repair Montreal

Specialized in-home Repair and Installation of Danby compact & full-size appliances for condos, apartments, and homes.


MONTREAL - WEST ISLAND - LAVAL - SOUTH SHORE

Brand Specialist

Our technicians are trained to focus on certain brands to improve efficiency

Give us a call, we will send a professional repairman to your home that specializes on your brand.

Danby Residential or Commercial appliances.

Flash Repair

438-700-9164

Our Danby Service


We service Danby compact refrigerators, chest & upright freezers, 18–24" dishwashers (built-in & portable), 20–24" ranges, and compact washers/dryers. Technicians carry common parts and provide clear, upfront pricing.

About Danby

Danby Dishwasher Repair Montreal

Fault/Code Condition/Description Solution
E1 Fill timeout / low pressure Open valve; clean inlet screen; test inlet valve; verify pressure.
E2 Drain error Clear filter, air gap and hose; test drain pump/impeller.
E3 Heating fault / low temp rise Test heater & NTC; inspect relay/control.
E4 Overflow/leak detected Dry base; check float/micro-switch; repair leak source.
E5 Circulation pump error Check pump windings/obstruction; replace circulation motor if failed.
E6 Temp sensor fault Ohm thermistor; repair harness; replace sensor/control.
E7 Turbidity/OWI error (if equipped) Clean sensor; check wiring; replace OWI.
U1 Door not latched Adjust latch/strike; replace latch switch if open.
U3 Key stuck / UI fault Reseat ribbon; replace console/UI.
PF Power failure Clear; verify supply/breaker/neutral.

Danby Range & Oven Repair Montreal

Fault/Code Condition/Description Solution
F1 Control fault / stuck key Power reset; replace EOC or keypad if recurring.
F2 Runaway temperature Test temp sensor/RTD and relays; replace failed component.
F3 Sensor open Measure RTD ~1080Ω @ 70°F; repair harness or replace.
F4 Sensor short Inspect shorts; replace RTD/control as required.
F5 Latch/door lock error (if self-clean) Test latch motor/switches; replace assembly.
Ign Gas ignition failure Check igniter draw (≥3.2A typical); replace igniter/valve.
Fan Cooling fan not running (if equipped) Test fan motor & tacho; replace fan.
PF Power failure Clear; verify supply/breaker/terminal block.
L2 Low line voltage (electric) Check supply wiring/outlet; involve electrician if needed.
Key Key stuck / UI fault Reseat ribbon; replace UI/clock.

Danby Refrigerator Repair Montreal

Fault/Code Condition/Description Solution
HI High temperature alarm Clean condenser; verify fans; check gasket; test sealed system.
d Door open Adjust hinges; test door switch; replace gasket if leaking.
E1/E2 Sensor faults Ohm NTCs; repair wiring; replace sensor/control.
DF Defrost error Test heater/bi-metal/ADC; replace failed part.
CF Compressor/inverter fault (select) Test start device/inverter; evaluate compressor.
FAN Evap/condenser fan error Test voltage & rotation; replace motor.
ICE Icemaker fault (if equipped) Run IM test; replace module, motor or valve.
rS Sealed system underperforming Leak/charge diagnostics by certified tech.
Filter Filter change reminder Replace filter; reset indicator.
PF Power failure Clear alarm; verify supply/surge protection.

Danby Washer Repair Montreal

Fault/Code Condition/Description Solution
E1 Lid open / lock fault Adjust strike; replace lid lock/switch.
E2 Fill fault / low pressure Open valves; clean screens; test inlet valve.
E3 Drain timeout Clear pump & hoses; replace drain pump if weak.
E4 Unbalance Redistribute load; level feet; check suspension.
E5 Motor fault Inspect capacitor/motor; replace failed components.
E6 Thermistor/NTC fault (select) Ohm sensor; replace if out of range.
E7 Door not closed (front models) Replace door lock assembly.
dE Door error Check latch & wiring; replace lock.
LE Drive overload Check basket/belt; motor windings; control.
PF Power failure Clear; verify outlet/breaker.

Danby Dryer Repair Montreal

Fault/Code Condition/Description Solution
E1 Overheat / hi-limit trip Clean lint & ducts; test thermostats/NTC.
E2 Heater open Check element continuity and relays; replace if failed.
E3 Motor fault Test motor/capacitor; replace if defective.
E4 Moisture sensor fault Clean bars; check harness; replace sensor PCB.
E5 Thermistor out of range Ohm NTC; replace sensor or control.
E6 Door switch fault Replace door switch if open/shorted.
E7 Control relay error Inspect board; replace main PCB.
AF Restricted airflow Clean exhaust path; check blower wheel.
L2 Low line voltage Verify supply/breaker/receptacle.
PF Power failure Clear and retest; confirm dedicated circuit.

Brands we
Repair and Install

North American brands
and
European brands.

Service
hours

Monday to Friday
7:00am - 9:00pm

Saturday
10:00am - 5:00pm

Sunday
12:00am - 5:00pm

Payment
Methods
Credit card
Debit
Contact Us

We service Montreal, Laval, West Island, South Shore.

438-700-9164