Hisense Appliance Repair Montreal

Hisense Appliance Repair Montreal

We service Hisense kitchen and laundry appliances with OEM-quality parts and precise diagnostics. Clear estimates, protected finishes, and a one-year parts & labour warranty.


MONTREAL - WEST ISLAND - LAVAL - SOUTH SHORE

Brand Specialist

Our technicians are trained to focus on certain brands to improve efficiency

Give us a call, we will send a professional repairman to your home that specializes on your brand.

Hisense Residential or Commercial appliances.

Flash Repair

438-700-9164

Our Hisense Service


We handle Hisense sealed-system cooling, inverter boards, fan systems, icemakers, range ignition & elements, dishwasher wash/heat/Drain, and laundry motors, pumps, and control modules. We aim for first-visit fixes and provide care instructions to prevent repeat issues.

About Hisense

Hisense Dishwasher Repair Montreal

Fault/Code Condition/Description Solution
E1 Water inlet/fill error Open supply; clean screen; replace inlet valve/flow meter.
E2 Drain timeout / restriction Clear filter/air gap/hoses; replace drain pump.
E3 Heating failure / low temp rise Test element/relay; replace heater or control.
E4 Leak/overflow detected (tray) Dry base; fix leak source; reset float/micro-switch.
E5 Wash motor fault Inspect impeller; replace circulation motor.
E6 Turbidity/NTC sensor fault Clean/replace sensor; check harness.
E7 Door/latch error Adjust door; replace latch switch.
E8 UI communication fault Reseat ribbon; replace UI or main board.
CL Control lock active Disable lock via panel.
PF Power failure Clear and retest; verify circuit.

Hisense Range & Oven Repair Montreal

Fault/Code Condition/Description Solution
F1 Main control/EEPROM fault Power reset; replace control if returns.
F2 Runaway oven temperature Verify RTD (~1080Ω @ 70°F) & relays; replace sensor/control.
F3/F4 Oven sensor open/short Ohm RTD; repair harness; replace sensor/board.
F5 Key stuck / UI fault Reseat ribbon; replace keypad/UI.
F7 Communication error Inspect connectors; replace board/UI.
F8 Cooling fan speed error Test/replace fan; check tacho output.
F9 Door latch error (self-clean) Replace latch motor/switch; align door.
IGN Ignition failure (gas) Replace igniter/module/valve; verify pressure.
LOC Control lock/Sabbath active Disable lock via panel.
PF Power failure Clear; verify supply/neutral/ground.

Hisense Refrigerator Repair Montreal

Fault/Code Condition/Description Solution
H / HI TEMP High temperature alarm Clean condenser; verify fans/compressor; sealed-system checks.
dO Door open / switch fault Adjust hinges; replace door switch/gasket.
E1/E2 Fridge/Freezer sensor error Ohm NTCs; replace sensor or board.
DEF Defrost failure (ice on evap) Test heater, fuse/bi-metal; board output.
FAN Evaporator or condenser fan error Replace fan; clear ice/debris; check tacho.
ICE Icemaker harvest/fill fault Run IM test; replace module/valve.
INV/COMP Inverter/compressor fault Check DC bus & windings; replace inverter/compressor.
UI/COM UI ↔ control comm error Reseat connectors; replace control/UI.
Filter Water filter reminder Replace filter; reset indicator.
PF Power failure Clear alarm; verify supply.

Hisense Washer Repair Montreal

Fault/Code Condition/Description Solution
E11 Fill time too long Open valves; clean screens; replace inlet valve.
E21 Drain timeout Clear pump/hoses; replace drain pump.
E23 Leak/flood switch active Dry base; locate leak; replace float/switch.
E41/E42 Door/lid lock fault Replace lock assembly; check strike.
E52 Motor tach signal fault Test motor/hall; belt; control/inverter.
E5A/E5E Motor/inverter thermal/comm Improve cooling; replace inverter.
E66 Heater relay stuck (front-load) Replace control or relay board.
E68 Heater leakage to ground Megger element; replace if shorted.
Ub Unbalance detected Level; inspect suspension/shocks.
PF Power failure Clear; verify supply.

Hisense Dryer Repair Montreal

Fault/Code Condition/Description Solution
tS/tF Thermistor short/open Ohm thermistor; replace sensor/control.
HE Heater fault (electric) Test element/relay/thermal cutoffs; replace failed part.
gH Gas heat failure Check igniter, coils, valves; airflow.
AF Restricted airflow Clean duct; correct length/kinks; verify blower.
E41 Door switch fault Replace door switch/latch.
L2 Low line voltage (electric) Check receptacle/breaker/terminal block.
MTR Motor not starting/overload Test capacitor/motor; replace if seized.
UI Keypad/UI error Replace UI or main board.
PF Power failure Reset and test; verify supply.
SENS Moisture sensor fault Clean bars; replace harness/sensor.

Brands we
Repair and Install

North American brands
and
European brands.

Service
hours

Monday to Friday
7:00am - 9:00pm

Saturday
10:00am - 5:00pm

Sunday
12:00am - 5:00pm

Payment
Methods
Credit card
Debit
Contact Us

We service Montreal, Laval, West Island, South Shore.

438-700-9164