Specialized in-home Repair and Installation of Electrolux premium kitchen and laundry appliances.
Our technicians are trained to focus on certain brands to improve efficiency
Give us a call, we will send a professional repairman to your home that specializes on your brand.
Electrolux Residential or Commercial appliances.
Flash Repair
We service Electrolux French-door & column fridges, induction/gas ranges and wall ovens, 18–24" dishwashers, and front-load laundry. OEM parts on hand and upfront pricing.
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| i10 | Fill fault | Open valve; clean screen; test inlet valve & pressure. |
| i20 | Drain fault | Clear filter/hoses; test drain pump. |
| i30 | Leak in base | Dry tray; inspect float switch; repair leak source. |
| i40 | OWI/turbidity fault | Clean sensor; check harness; replace OWI. |
| i50 | Wash motor error | Check circulation pump windings/obstruction; replace motor. |
| i60 | Heating fault | Test element & NTC; verify control relay. |
| i70 | Temp sensor fault | Ohm thermistor; replace if out of range. |
| i80 | Control fault | Power reset; replace main board if persistent. |
| UO | Vent fan/open vent | Test vent fan motor; replace if failed. |
| PF | Power failure | Clear; verify supply. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F10 | Runaway temperature | Test RTD & relays; replace failed part. |
| F30/F31 | Oven sensor open/short | Ohm RTD ~1080Ω @ 70°F; replace if out of spec. |
| F90 | Door lock/latch error | Test lock motor & switch; replace latch assembly. |
| E0 | Keypad not responding | Reseat ribbon; replace UI. |
| F14 | Touch panel fault | Replace touch control/overlay. |
| F11 | Shorted key | Replace keypad/touch module. |
| F20 | Communication error | Inspect harness/control; replace board. |
| Ign | Ignition failure (gas) | Measure igniter current; replace igniter or valve. |
| Fan | Cooling fan fault | Replace cooling fan motor/tacho. |
| PF | Power failure | Clear and retest. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| SY EF | Evaporator fan fault | Test fan motor/feedback; replace motor. |
| SY CE | UI to control comms error | Inspect connectors; replace UI/control. |
| d | Door open alarm | Adjust hinges/level; replace gasket/switch if needed. |
| H | High temp alarm | Clean condenser; check fans; sealed-system test. |
| E3 | Defrost fault | Test heater/bi-metal/timer/ADC; replace failed part. |
| Ice | Icemaker fault | Run IM test; replace module/motor/valve. |
| E1/E2 | Thermistor out of range | Ohm sensors; replace NTC/control. |
| CF | Compressor/inverter error | Test inverter & compressor windings. |
| Filter | Filter reminder | Replace filter; reset. |
| PF | Power failure | Clear; verify circuit/surge. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E11 | Fill fault | Clean inlet screens; test valves; verify pressure. |
| E13 | Leak detected | Inspect tub-to-pump, valves; repair leak source. |
| E21 | Drain fault | Clear filter/hoses; replace pump if weak. |
| E23/E24 | Pump/board triac fault | Test pump & board; replace failed part. |
| E35 | Overfill / pressure sensor | Check pressure hose/switch; replace switch. |
| E41/E42 | Door lock open | Replace door lock assembly. |
| E52 | Tacho/motor fault | Test motor & speed sensor; replace as needed. |
| E66 | Heater relay fault | Replace heater relay/control. |
| E68 | Heater leakage to ground | Insulation test; replace heater. |
| EF5 | Unbalance detected | Level unit; inspect shocks/springs. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E64 | Heater open | Test heater & relays; replace failed part. |
| E66 | Heater relay fault | Replace control/relay board. |
| E68 | Leakage to ground | Insulation test; replace element. |
| E8C | Low airflow | Clean vent & lint path; check blower. |
| E5B | No heat (gas/electric) | Check igniter/gas valve or element/thermostats. |
| E4A | Dry time too long | Verify venting; check moisture sensor. |
| E32 | Humidity sensor fault | Clean bars; replace sensor PCB. |
| E21 | Drain pump (condensing models) | Clear hoses/pump; replace pump. |
| E41 | Door switch fault | Replace door switch. |
| PF | Power failure | Clear and retest. |