| Fault/Code | Condition/Description | Solution |
|---|---|---|
| H20 | Fill fault / low water | Open valve; clean inlet screen; test inlet valve & pressure. |
| C2 | Drain time exceeded | Clear filter, air gap and hose; test drain pump. |
| C3 | Flood / leak detected in base | Dry base; inspect float switch; repair leak source. |
| C1 | Water level error / overfill | Check pressure switch/OWI; inspect valve sticking. |
| Ftd | Heater not reaching temp | Test element & NTC; inspect control relay. |
| 999 | Control error (service) | Power reset; replace main board if persistent. |
| Cup | Vent fan/lid error (select) | Test vent motor; replace if failed. |
| LE | Leak error (newer platforms) | Locate and correct leak; dry tray; reset. |
| PF | Power failure | Clear; verify supply/breaker. |
| Key | Key stuck / UI fault | Reseat ribbon; replace UI/console. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F20/F2 | Runaway temperature | Test RTD (~1080Ω @ 70°F) & relays; replace failed part. |
| F30/F31 | Oven sensor open/short | Repair harness; replace RTD/control. |
| F97/F96 | Cooling fan speed/feedback low | Test fan/tacho; replace fan or board. |
| F7 | Keypad stuck / shorted key | Reseat ribbon; replace touch panel. |
| F9 | Door lock/latch error (self-clean) | Test lock motor/switch; replace latch assembly. |
| ERR-IGN | Ignition failure (gas) | Measure igniter current ≥3.2A; replace igniter/valve. |
| F76/F79 | UI ⇄ control communication | Inspect connectors; replace board/UI. |
| PF | Power failure/interruption | Clear; verify supply/neutral/ground. |
| LOC | Control lock active | Unlock per manual; verify keypad. |
| Probe | Temp probe short/open | Replace probe or jack; check control. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| H | High temperature alarm | Clean condenser; test fans; sealed-system diagnostics. |
| d | Door open/ajar | Level cabinet; adjust hinges; replace switch/gasket. |
| FF / FZ | Fresh food / freezer sensor fault | Ohm NTCs; repair harness; replace sensor/control. |
| DF | Defrost failure | Test heater/defrost sensor; replace board if no drive. |
| SY EF | Evaporator fan feedback error | Replace motor; clear ice; check wiring. |
| INV | Inverter/compressor error | Test inverter DC & signals; replace inverter/compressor. |
| ICE | Icemaker harvest/fill fault | Run IM test; replace module, motor or valve. |
| Filter | Water filter reminder | Replace filter; reset indicator. |
| CF | Control fault | Power reset; replace main board if persistent. |
| PF | Power failure | Clear alarm; verify supply/surge. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F26 | Lid lock not engaging (top-load) | Adjust strike; replace lid lock assembly. |
| F21 | Drain timeout | Clear pump/hoses; replace drain pump if weak. |
| F45 | Inverter/drive communication | Inspect harness; replace inverter or control. |
| E43 | Door lock error (front-load) | Replace door lock assembly. |
| E22 | Fill fault / low pressure | Open valves; clean inlet screens; test inlet valve. |
| E51 | Motor tachometer fault | Test motor & hall sensor; replace as required. |
| E66 | Heater relay fault (front-load) | Replace board/relay; test element. |
| E68 | Heater leakage to ground | Insulation test; replace heater. |
| UB | Unbalance detected | Level cabinet; inspect shocks/suspension. |
| PF | Power failure | Clear; verify outlet/breaker. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E64 | Heater open (electric) | Test element & relays; replace failed part. |
| E80 | Low airflow / restriction | Clean vent & lint path; check blower wheel. |
| E5B | No heat (gas/electric) | Check igniter/gas valve or element/thermostats. |
| E32 | Moisture sensor fault | Clean sensor bars; check harness; replace PCB. |
| E41 | Door switch fault | Replace door switch/latch. |
| L2 | Low line voltage | Verify supply/breaker/receptacle. |
| tS/tF | Thermistor short/open | Ohm NTC; replace sensor/control. |
| E61 | Motor fault | Test motor/capacitor; replace if defective. |
| PF | Power failure | Clear and retest. |
| LOC | Control lock active | Unlock per manual; verify UI. |