We repair compact & full-size Magic Chef appliances: fridges & freezers, gas/electric ranges, countertop & built-in dishwashers, and portable laundry. Upfront quotes, OEM-quality parts, and a one-year parts & labour warranty.
Our technicians are trained to focus on certain brands to improve efficiency
Give us a call, we will send a professional repairman to your home that specializes on your brand.
Magic Chef Residential or Commercial appliances.
Flash Repair
Magic Chef offers value-focused appliances popular in condos, student housing and secondary suites. We carry common pumps, valves, sensors, boards, igniters, elements and fans to complete many repairs on the first visit.
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E1 | No/low water fill | Open supply; clean screen; test inlet valve/flow sensor. |
| E2 | Drain timeout | Clear filter/hoses; test drain pump. |
| E3 | Heating fault / no temp rise | Ohm element & NTC; inspect relay; replace failed part. |
| E4 | Overflow/leak detected | Dry base; find leak; reset float/pressure. |
| E5 | Turbidity/NTC sensor error | Replace sensor; check harness. |
| E6 | Water inlet sensor / flow meter | Replace flow sensor; verify pressure. |
| E8 | Circulation motor fault | Test wash motor; replace pump assembly. |
| E9 | EEPROM/board fault | Power reset; replace control if persistent. |
| CL | Child lock engaged | Hold lock combo to release. |
| PF | Power fail | Clear; verify circuit. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F1 | Control board fault | Power reset; replace clock/EOC if returns. |
| F2 | Runaway temperature | Test RTD (~1080Ω @ 70°F); check relay stuck. |
| F3/F4 | RTD open/short | Repair harness; replace sensor or board. |
| F5 | Keypad/UI error | Reseat ribbon; replace UI. |
| F7 | Function key shorted | Replace touch membrane/UI. |
| F8 | Cooling fan fault (select) | Replace fan motor/relay. |
| F9 | Latch/lock error | Service lock motor & switches. |
| IGN | Ignition failure (gas) | Replace hot surface igniter/spark & verify pressure. |
| PF | Power failure | Clear; verify supply. |
| LOC | Control lock active | Unlock via panel. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| HI | High temperature alarm (select) | Clean condenser; verify fans/compressor; sealed-system checks. |
| dO | Door open / switch fault | Replace switch; adjust hinges/gasket. |
| SENS | Thermistor out of range | Ohm sensor; replace NTC or board. |
| DF | Defrost failure / ice-up | Test heater/bi-metal/timer/ADC. |
| FAN | Evap/condenser fan error | Replace motor; clear ice/debris. |
| IM | Icemaker harvest/fill fault | Run test; replace module/valve. |
| COMP | Compressor/inverter fault | Test start device/inverter; replace as required. |
| Filter | Water filter reminder (select) | Replace filter; reset. |
| CF | Control fault | Power reset; replace board if persistent. |
| PF | Power failure | Clear alarm; verify supply. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E1 | No/low water fill | Open valves; clean screens; replace inlet valve. |
| E2 | Drain timeout | Clear pump/hoses; replace drain pump. |
| E3 | Unbalance | Redistribute load; level unit; inspect suspension. |
| E4 | Door/lid lock error | Replace lock; adjust strike. |
| E5 | Pressure sensor error | Check hose; replace sensor. |
| E6 | Motor/tacho error | Inspect motor, belt (if used) & hall; replace control if needed. |
| E7 | Overfill | Replace valve; verify pressure tube. |
| tE | Temp sensor fault (combo) | Replace NTC/control channel. |
| CL | Child lock | Unlock via panel. |
| PF | Power failure | Clear; verify supply. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| tE1/tE2 | Thermistor open/short | Ohm NTC; replace sensor/control channel. |
| HE | No heat / heater open | Test element, relays/thermostats; replace failed part. |
| AF | Restricted airflow | Clean lint path; verify vent & blower. |
| dO | Door switch fault | Replace door switch; adjust strike. |
| MTR | Motor won’t start | Test motor/run cap; replace as needed. |
| PF | Power failure | Clear; verify receptacle/breaker. |
| LOC | Control lock | Unlock via panel. |
| E5 | Overheat trip | Check venting; reset hi-limit; replace if weak. |
| E9 | Board/relay fault | Replace control. |
| tS/tF | Exhaust sensor short/open | Replace NTC. |