| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F6-E1 | No/low fill | Open supply; clean screens; test valve/flow. |
| F9-E1 | Drain timeout | Clear hoses/air gap; test drain pump. |
| F7-E1 | Heater not heating | Ohm element/NTC; replace relay/board. |
| F3-E3 | OWI/turbidity fault | Clean sensor; replace OWI. |
| F4-E3 | Wash motor not running | Replace pump/motor assembly. |
| F8-E4 | Overfill/leak | Dry base; fix leak; reset float. |
| F2-E1/E2 | Stuck key / UI mismatch | Reseat ribbon; replace UI/control. |
| PF | Power failure | Clear; confirm circuit. |
| CL | Control lock | Unlock via panel. |
| dU | Detergent door fault | Replace dispenser. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F2/F20 | Runaway temp | Test RTD & relays; replace sensor/control. |
| F3/F4 | RTD open/short | Repair harness; replace RTD/board. |
| F7-E0/E1 | Keypad/UI fault | Reseat ribbon; replace UI. |
| F8-E3 | Cooling fan slow | Test fan/tacho; replace as needed. |
| F9/E0 | Door lock fault | Service lock motor/switches. |
| IGN | Ignition failure | Replace igniter/valve; verify pressure. |
| PF | Power failure | Clear; verify supply. |
| LOC | Control lock | Unlock per manual. |
| Com | UI ⇄ control comm error | Inspect harness; replace PCB. |
| Probe | Meat probe error | Replace probe/jack; retest. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| PO | Power outage | Acknowledge; verify temps. |
| H2O/Filter | Replace water filter | Install new filter; reset. |
| dO/d1 | Door open/switch | Adjust hinges; replace switch/gasket. |
| SY/CF | Control ⇄ UI comm | Reseat connectors; replace board/UI. |
| E0x | Sensor faults | Ohm NTCs; replace sensor/control. |
| ICE | Icemaker faults | Run IM test; replace module/valve. |
| FAN | Fan feedback low | Replace fan; clear debris. |
| DF | Defrost failure | Heater/bi-metal/ADC diagnostics. |
| INV/COMP | Inverter/compressor | Test inverter DC/windings; replace as needed. |
| PF | Power fail | Clear alarm. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F9-E1 | Long drain | Clear pump/hoses; replace pump. |
| F8-E1 (LO FL) | No/low fill | Open valves; clean screens; replace inlet valve. |
| F5-E2 | Lid/door lock | Adjust strike; replace lock. |
| F7-E1 | Shifter/actuator | Replace actuator/control as indicated. |
| F0-E5 | Off-balance | Redistribute; level; check suspension. |
| F7-E7/E9 | Motor speed | Inspect belt, basket, motor & cap. |
| F3-E1 | Temp sensor | Test thermistor; wiring; control. |
| F2-E1 | Stuck key | Clean keypad; replace UI. |
| F6-E3 | UI ⇄ control comm | Check connectors/power quality; replace board. |
| SD | Excess suds | Use HE detergent; rinse cycle; clean dispenser. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| AF / F4-E3 | Restricted airflow | Clean duct/lint path; verify blower & thermistor. |
| L2 | Low line voltage | Check breaker/receptacle/terminal block. |
| PF | Power failure | Clear and restart; inspect supply. |
| F01 | Main control failure | Replace control; inspect harness/thermal events. |
| F3-E2 | Exhaust thermistor open/short | Ohm thermistor; replace as needed. |
| F4-E1 | Heater relay/element | Check element continuity, relays & hi-limit. |
| F2-E1 | Stuck key/UI | Clean keypad; reseat ribbon; replace UI. |
| F2-E3 | UI ⇄ control mismatch | Program/replace UI or control. |
| E1/E2 | Thermistor out of range (legacy) | Test/replace thermistor; verify vent. |
| tS/tF | Moisture sensor fault | Clean bars; check harness; replace sensor. |