We service Fulgor Milano pro-style ranges, wall ovens, gas & induction cooktops, hoods and warming drawers. Certified technicians carry common OEM parts and provide clear, upfront pricing. After each repair, we fully test the appliance, answer questions, and back the work with a one-year parts & labour warranty.
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F1 / F01 | Control/keyboard fault | Power reset; reseat ribbon; replace UI/touch panel or EOC. |
| F2 | Runaway temperature / overheat | Test RTD and safety stats; check stuck relays; replace RTD/control. |
| F3 | Oven sensor (RTD) open | ~1080Ω @ 70°F expected; repair harness or replace sensor. |
| F4 | Oven sensor short | Inspect shorts to chassis; replace RTD or control. |
| F8 | Cooling fan speed/feedback low | Verify fan spins freely; test tacho; replace fan or board. |
| F9 | Door lock/latch fault (self-clean) | Test lock motor & switches; repair wiring; replace latch assembly. |
| IGN | Ignition failure (gas bake/broil) | Measure igniter current (≥3.2–3.6A typical); replace igniter/valve. |
| E-Comm | UI ⇄ control communication error | Inspect connectors and voltage; replace board/UI if persistent. |
| PF | Power failure/interruption | Clear; verify supply/neutral/ground; retest. |
| LOC | Control lock active | Hold unlock per model; confirm keypad. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F01/F02 | Keypad or UI fault | Reseat ribbon; replace touch UI or overlay. |
| F03/F04 | Temp sensor open/short | Ohm RTD; repair wiring; replace sensor/control. |
| F05 | Overheat / safety stat trip | Reset/replace safety stat; check fans/airflow. |
| F07 | Convection fan error | Test motor & tacho; replace fan or board. |
| F08 | Cooling fan error | Verify supply & feedback; replace cooling fan. |
| F09 | Door lock/latch fault | Service lock motor & switches; replace assembly if needed. |
| F10 | Relay stuck / triac short | Replace control; inspect elements for shorts. |
| Err-SC | Steam system fault (steam/combination) | Descale; test pump/NTC; replace module. |
| PF | Power failure | Clear; verify circuit/neutral/ground. |
| LOC | Child lock active | Unlock per manual; verify UI. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| IGN | No ignition / clicking no flame | Check electrode gap, spark module, valve & pressure; replace failed part. |
| E2 | Induction over-temp / NTC fault | Clean vents; test NTC; replace sensor/control. |
| E3 | IGBT overheat (induction) | Verify cooling fan; thermal paste; replace module. |
| E5 | Pan detection error | Use compatible cookware; test coil sensors; replace board. |
| E6 | Supply voltage out of range | Verify L1/L2/N; correct wiring. |
| LOC | Control lock active | Hold lock combo to clear; check keypad. |
| SPK | Continuous sparking | Dry spills; replace spark switch or module. |
| Hi | Surface temp high | Allow cool down; check fan & airflow. |
| Err | General control error | Power reset; replace PCB if recurring. |
| PF | Power failure | Confirm dedicated circuit; retest. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| FAN | Motor won’t start / hums | Test capacitor & windings; clear obstructions; replace motor/control. |
| LED | Lights flicker/not working | Replace LED driver or modules; check wiring. |
| KEY | Touch panel unresponsive | Reseat ribbon; replace touch PCB. |
| SPD | Fan speeds inoperative | Replace control/triac pack. |
| VIB | Excess vibration/noise | Tighten mounts; balance blower wheel. |
| REM | Remote blower no response | Verify harness; replace remote motor/control. |
| ODOR | Poor capture | Correct duct size/length; ensure make-up air. |
| NOISE | Rattle/scrape | Re-seat blower; inspect housing & filters. |
| PF | Power failure | Verify supply & breaker; surge protection. |
| LCK | Control lock active | Unlock per manual; confirm keypad. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| NTC | Temperature sensor fault | Ohm sensor; replace NTC/control as required. |
| H1 | Overheat / hi-limit trip | Reset/replace safety stat; inspect airflow. |
| ELM | Element open / no heat | Check element continuity & relays; replace failed part. |
| FAN | Convection fan not running (if equipped) | Replace fan motor; verify supply/tacho. |
| KEY | Knob/touch not responding | Replace potentiometer or touch PCB. |
| DOOR | Drawer switch fault | Adjust/replace door interlock switch. |
| RLY | Relay stuck/shorted | Replace control PCB; inspect wiring. |
| PF | Power failure | Verify circuit; retest. |
| NOISE | Rattle from slides | Service/replace rails; re-seat pan. |
| LOC | Control lock active | Unlock per manual; confirm UI. |