Need AEG appliance repair in Montreal? Our certified technicians provide in-home AEG service across Montreal, the West Island, Laval, and the South Shore. We diagnose quickly, carry common AEG/Electrolux parts to resolve most issues on the first visit, and give clear, upfront pricing before any work begins.
After the repair, your technician will fully test the appliance, answer your questions, and share simple maintenance tips to help prevent future problems. Every job is backed by a one-year warranty on parts and labour for peace of mind.
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| F1 | Main control fault | Power reset 1–2 minutes; inspect harness/shorts; replace control if code returns. |
| F2 | Runaway temperature / overheat | Check cavity temp vs setpoint; test temperature sensor (RTD) and relays; replace failed part. |
| F3 | Temperature sensor open | Ohm sensor per spec; repair wiring or replace sensor. |
| F4 | Temperature sensor shorted | Inspect harness for shorts; replace sensor/control if near 0Ω. |
| F8 | Cooling fan speed below target | Verify fan spins freely and tacho feedback; replace fan or control. |
| F9 | Door lock/latch fault (pyro) | Test latch motor & switches; repair wiring; replace latch assembly. |
| SAFE | Child safety lock active | Hold lock/unlock per panel legend to restore keypad. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| i10 | No/low water fill | Open valves; clean inlet screen; test fill valve & pressure; replace valve if defective. |
| i20 | Drain problem / restriction | Clear filter, sump & hoses; check air gap; test/replace drain pump. |
| i30 | Leak detected / anti-flood activated | Inspect base tray & float; dry unit; correct leak source and hoses. |
| i50 | Wash/circulation motor error | Check harness at pump & control; test motor; replace motor or control as needed. |
| i60 | Heating fault / low temp rise | Test element & NTC; verify fill level; repair control or wiring as required. |
| iF0 / iC0 | Configuration/UI fault | Reseat console ribbon; reconfigure; replace UI or control if persistent. |
| PF | Power failure during cycle | Clear and run diagnostics; check supply if recurring. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E60 | Heating circuit fault (generic family code) | Check heater/heat-pump system, NTCs, relays; clear lint/airflow; replace failed parts. |
| E50 | Motor/tacho fault | Inspect belt, drum, motor & tacho; test harness; replace motor/control as required. |
| E40 | Door/lid not closed / switch fault | Verify latch & switch operation; adjust or replace door switch. |
| E91 | UI ↔ main board communication | Reseat connectors; check supply; replace board if persistent. |
| E32 | Moisture sensor issue | Clean sensor bars; check harness; replace sensor assembly if failed. |
| PF | Power failure / interruption | Clear and restart; inspect cord, outlet, or breaker if recurring. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| H | High temperature alarm | Acknowledge; verify cooling, door seal and airflow; diagnose sealed-system if needed. |
| d | Door open alarm | Close door fully; test door switch and hinges; adjust or replace as needed. |
| E (sensor) | Thermistor/sensor out of range | Ohm relevant sensors; replace failed sensor or control. |
| Filter | Replace water filter reminder (if equipped) | Install new filter; reset indicator per model instructions. |
| Lock | Controls locked (child lock) | Hold lock/unlock per panel legend to restore keypad. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E10 | No/low water fill | Open water valves; clean inlet screens; test/replace inlet valve. |
| E11 | Fill timeout | Check pressure level hose, valve and supply; replace valve if weak. |
| E20 | Long drain / no drain | Clear pump filter & hoses; check standpipe height; test/replace drain pump. |
| E21 | Drain pump blocked | Remove obstruction; test impeller and winding; replace pump if failed. |
| E40 | Door lock not engaging | Inspect strike/lock; replace door lock assembly if faulty. |
| E50 | Motor/triac/tacho fault | Test motor, capacitor (if fitted), belt & tacho; repair wiring or control. |
| E60 | Heating problem | Test element & NTC; inspect relay; replace failed component. |
| E90 | Configuration/communication error | Check connectors; reconfigure; replace UI or main board if persistent. |
| SUd / Excess Suds | Excess suds detected | Use HE detergent; run rinse; clean dispenser; check pressure hose. |