We service Gaggenau’s modular cooking systems, convection/steam wall ovens, flex induction cooktops, integrated refrigerators/freezers, quiet dishwashers, and professional hoods. Our technicians are familiar with premium German design and provide careful, OEM-backed repairs. All repairs include functional testing and a one-year parts & labour warranty.
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E011 | Temperature sensor short | Check RTD resistance; replace sensor or control. |
| E012 | Temperature sensor open | Inspect wiring; replace sensor. |
| E115 | Overheating / cooling fan issue | Check cooling fan; clear vents; replace fan or control. |
| E522 | Communication error UI ↔ control | Check connectors; replace board. |
| E607 | Steam generator fault | Check pump, heater, descale; replace as needed. |
| E609 | Water tank missing/empty | Fill or insert tank; test float switches. |
| E710 | Door lock error | Test lock motor & switches; replace latch. |
| E720 | Relay stuck | Replace control/relay board. |
| E990 | General control fault | Power reset; replace module. |
| PF | Power failure | Clear; verify supply. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E2 | Induction NTC sensor fault | Test sensor; replace coil module. |
| E3 | IGBT overheating | Verify cooling fan; replace module. |
| E6 | Supply voltage error | Check L1/L2/N; correct wiring. |
| E9 | Pan detection error | Use compatible cookware; replace sensor/module. |
| IGN | Ignition failure (gas) | Check electrode, spark module, valve. |
| SPK | Continuous sparking | Dry spills; replace switch/module. |
| LOC | Control lock active | Unlock per manual. |
| Err | General electronics fault | Reset power; replace module. |
| FAN | Cooling fan error | Replace blower/fan. |
| PF | Power failure | Clear alarm; verify supply. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E1 | Fridge sensor fault | Test NTC; replace sensor/control. |
| E2 | Freezer sensor fault | Replace NTC; inspect wiring. |
| E3 | Evap sensor fault | Check thermistor & harness. |
| d | Door open alarm | Level cabinet; replace switch/gasket. |
| H | High temp alarm | Clean condenser; test fans. |
| DF | Defrost error | Test heater/bi-metal; replace board. |
| INV | Inverter/compressor error | Test inverter DC; replace compressor/inverter. |
| ICE | Icemaker fault | Run IM test; replace motor/module. |
| CF | Control failure | Replace board. |
| PF | Power failure | Clear alarm; verify supply. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| E01 | Water protection activated | Check base tray for water; repair leaks. |
| E09 | Heater/flow heater fault | Replace heater/flow assembly. |
| E15 | Leak in base | Dry base; repair leak source. |
| E24 | Drain error | Clear filter/hoses; test pump. |
| E25 | Drain pump blocked | Clear impeller; replace pump. |
| E27 | Mains voltage too low | Check supply voltage. |
| E31 | NTC fault | Replace sensor. |
| E32 | Flow sensor fault | Replace flow meter. |
| E36 | Heat pump error | Replace heater/board. |
| PF | Power failure | Clear and retest. |
| Fault/Code | Condition/Description | Solution |
|---|---|---|
| FAN | Fan not starting | Test capacitor & windings; replace motor/control. |
| LED | LED lights flicker/fail | Replace LED drivers/modules. |
| SPD | Fan speeds not changing | Replace control/triac pack. |
| KEY | Touch keys not responding | Replace keypad/control. |
| REM | Remote control error | Reprogram or replace receiver. |
| VIB | Vibration/noise | Balance blower; replace bearings. |
| FIL | Filter indicator active | Clean/replace filters; reset timer. |
| ODOR | Poor capture | Correct ducting/CFM. |
| PF | Power failure | Check circuit; reset. |
| LOC | Control lock | Unlock per manual. |